PURPOSE: The purpose of this study was to translate and cross-culturally adapt the UEFI into Modern Standard Arabic language and to examine its psychometric properties among patients with upper extremity musculoskeletal disorders. MATERIALS AND METHODS: Translation and cross-cultural adaptation were done following Beaton's guidelines. Internal consistency, test-retest reliability, measurement error and floor and ceiling effects for the Arabic UEFI were tested among 109 patients with upper extremity musculoskeletal disorders. Construct validity of the Arabic UEFI was also examined. RESULTS: Translation and cross-cultural adaptation processes were generally smooth with no major issues. The Arabic UEFI was considered appropriate and comprehensible by the participants. Internal consistency for Arabic UEFI was adequate (Cronbach's alpha = 0.96). Test-retest reliability for Arabic UEFI was excellent with ICC(2,1)=0.92. Measurement error was acceptable with a standard error of measurement of 5.5 and minimal detectable change of 12.8 points. Arabic UEFI shows no floor or ceiling effects. The results supported the majority of the construct validity predefined hypotheses (78%) supporting the construct validity of Arabic UEFI as a measure of upper extremity function. CONCLUSION: The Arabic UEFI is an appropriate, valid and reliable outcome measure for Arabic-speaking patients with upper extremity musculoskeletal disorders.Implication for Rehabilitation:The Arabic UEFI is an acceptable, clear and comprehensible outcome measure.The Arabic UEFI has excellent internal consistency, test-retest reliability, and acceptable measurement error with no floor and ceiling effects.The Arabic UEFI is a valid measure of upper extremity activity limitation.


Full citation

Aljathlani MF, Alshammari MO, Alsuwaygh MA, Al-Mutairi MS, Aljassir FF, Bindawas SM, Alnahdi AH. Cross-cultural adaptation and validation of the Arabic version of the upper extremity functional index. Disabil Rehabil. 2021 Jul 6:1-7. doi: 10.1080/09638288.2021.1947396. Epub ahead of print. PMID: 34227453.


Methodology

Methods Condition Gender Age Country Setting Sample size
with upper extremity musculoskeletal disorders. Saudi Arabia
Healthcare Facility 109

Number of items

15 items

Training

Measure does not require training

Required time

6-30 min